Les exposés écrits du congrès ont été publiés dans la langue dans laquelle ils ont été soumis à l’ATC.
An asphalt concrete (AC) mixture design is typically carried out to select a desired combination of aggregates and asphalt binder to meet some specified volumetric and stability requirements using either Marshall or SuperPave (SP) methods. However, none of these methods, explicitly set the limiting criteria and their targets for AC mix field performance in terms of rutting, fatigue cracking, thermal cracking and moisture related stripping resistance. The balanced mix design (BMD) approach attempts to make a good balance between the above specified field performance requirements with an appropriate combinations of mix constituents and their properties. The available performance tests include: i) Hamburg Wheel Track Test (HWTT) for rutting and moisture stripping; ii) Illinois Flexibility Index Test (I-FIT) or Indirect Tensile Cracking Test (CTIndex) for fatigue cracking potential; and iii) Fracture Energy of Asphalt Mixtures Using the Semicircular Bend Geometry (SCB) for fatigue and thermal cracking resistance. A study is being undertaken by Manitoba Transportation and Infrastructure (MTI) to characterize Manitoba’s local AC mixes and establish the acceptable thresholds for the above specified BMD parameters.
Twenty two AC mix samples have been collected as of March 2026 from different project sites. Hamburg Wheel Track (HWT), I-FIT, Ideal-CT, SCB Fracture energy and resilient modulus testing on these samples have been completed or are in progress. These mixes include Bit. B (Marshall Mix), SP12.5 and SP19.0 with different types of aggregate, design traffic loads, asphalt binder grades and RAP contents. The results showed that tested AC mixes met rutting performance requirements with SP mixes showing superiority over Bit. B mixes. Few AC mixes showed potential for stripping. Mixes with polymer modified asphalt binders showed better fatigue cracking performance than mixes with standard PG XX-34 binders. The results of Ideal-CT test seemed to be inconsistent. Mixes that were tested so far for fracture energy met the thermal cracking criteria. This paper presents the details of the various tests, their results, analysis, findings and the resulting recommendations.